Hendrick Lexus - Charlotte, NC
Area: 57,000 SF (single story)
Type: IV
Occupancy Classification: Business
Mechanical: Fully heated and air conditioned; packaged equipent; carbon monoxide
exhaust system
Plumbing: Includes above ground oil separation system
Fire Protection: Fully sprinklered (wet pipe)
Special Considerations: Fully air-conditioned service bays
Tim Marburger Dodge - Charlotte, NC
Area: 51,000 SF (single story)
Type: IV
Occupancy Classification: Business
Mechanical: Fully heated and air conditioned; packaged equipent; carbon monoxide
exhaust system
Plumbing: Includes above ground oil separation system
Fire Protection: Fully sprinklered (wet pipe)
Special Considerations: Fully air-conditioned service bays
Hendrick Honda - Charlotte, NC
Area 60,700 SF (two story)
Type: IV
Occupancy Classification: Business
Mechanical: Fully heated and air conditioned; packaged equipment; carbon monoxide
exhaust system
Plumbing: Includes above ground oil separation system
Fire Protection: Fully Sprinklered (wet pipe)
Special Considerations: Fully air-conditioned service bays
Fire Station Number 1 - Charlotte, NC
Area: 25,000 SF (two story)
Type: IV
Occupancy Classification: Residential
Mechanical: Air-cooled reciprocating chiller; gas-fired boilers with 4-pipe
fan coils; special truck exhaust system
Plumbing: Grease interceptor system
Fire Protection: Fully sprinklered (residential sprinkler system)
Special Considerations: Apparatus-bay truck exhaust system
Gastonia Police Station - Gastonia, NC
Area: 73,700 SF (two story)
Type: IV
Occupancy Classification: Business
Mechanical: Air-cooled reciprocating chillers; gas-fired boiler;
variable volume dual duct air distribution system
Plumbing: Fully handicapped accessible
Fire Protection: Unprotected
Special Considerations: Indoor gymnasium and locker area
Ballantyne - Charlotte, NC
Area: Multiple Buildings (multiple stories)
Type: IV
Occupancy Classification: Business
Mechanical: Air-cooled chiller with variable volume air distribution; all
electric
Plumbing: Fully accessible group toilets
Fire Protection: Fully sprinklered (wet pipe)
Special Considerations: Shell construction with tenant upfit
Maple Springs UMC - Winston-Salem, NC
Area: 36,300 SF (two story)
Type: V
Occupancy Classification: Assembly, Educational
Mechanical: Water source heat pumps with open cooling tower and gas-fired
boiler; exhaust system for kitchen
Plumbing: Grease interceptor system
Fire Protection: Unprotected
Special Considerations: Water source heat pump system; commercial kitchen
US Post Office - Albemarle, NC
Area: 10,650 SF (single story)
Type: IV
Occupancy Classification: Business
Mechanical: Air-cooled, gas-fired rooftop units
Plumbing: Handicapped accessible
Fire Protection: Unprotected
Special Considerations: Lookout gallery and postal inspector's access